GENERATOR WITH DIESEL ENGINE IVECO

Serie IV

New product

Generators IV series, equipped with an IVECO engine of 1500 RPM and a frequency of 50 Hz, has a power range which comprises of 12 to 550 Kva, cooled by water.

Available in the following versions:

  • Open
  • Soundproof

Models available with Diesel engine.

More details

Add to wishlist

Data sheet

TRADEMARKFPT INDUSTRIAL - IVECO
RPM1500
POWER ( KVA )32 a 550
HZ50
VOLTAJE400 / 230
COOLING SYSTEMWATER

More info

MORE INFORMATION


Generator recommended for situations where there is no mains power or as backup or safety equipment when cutting and / or power failures occur.

The mobile elements, distribution belt, fan, etc., and those parts which during operation acquire high temperatures, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of Machinery Safety Directive 2006/42.

SERIES MODELS


SERIE IV-E

ENGINEPOWER (KVA)DIMENSIONS (MM)
( LENGTH x WIDTH x HEIGHT )
REF.TRADEMARKMODELESPPRPHZR.P.MVOLTAGEOPEN
SOUNDPROOF
IV33EIVECOF32SM1A3328501500400/2301500 x 630 x 1350

1750 x 830 x 1120
IV44EIVECOF32SM1A4440501500400/2301750 x 740 x 1620

2380 x 970 x 1420
IV55EIVECONEF45AM25550501500400/2301750 x 740 x 1620

2380 x 970 x 1420
IV66EIVECON45 SM1A6660501500400/2301.750 x 740 x 1.650

2.380 x 970 x 1.430
IV82EIVECON45 SM2A8275501500400/2302000 x 750 x 1700

3000 x1030 x 1675
IV90EIVECON45 SM39080501500400/2302000 x 750 x 1700

3000 x1030 x 1675
IV110EIVECON45 TM2A110100501500400/2302000 x 750 x 1700

3000 x1030 x 1675
IV131EIVECON45 TM3131120501500400/2302000 x 750 x 1700

3000 x1030 x 1675
IV143EIVECON67 TM2A143130501500400/2302500 x 850 x 1860

3000 x1030 x 1675
IV165EIVECON67 TM4165150501500400/2302.500 x 900 x 2.060

3.380 x 1.130 x 2.000
IV187EIVECON67 TM4187170501500400/2302500 x 900 x 2060

3380 x 1130 x 2000
IV222EIVECON67 TM7222200501500400/2303060 x 850 x 2100

3380 x 1130 x 2000
IV275EIVECOC87 TE3275250501500400/2303060 x 850 x 2100

3380 x 1130 x 2000
IV332EIVECOC87 TE4332305501500400/2303060 x 850 x 2100

3380 x 1130 x 2000
IV385EIVECOCTE13 TE2A385350501500400/2303.410 x 1.300 x 2.100

3.880 x 1.530 x 2.200
IV440EIVECOC13 TE3A440400501500400/2303320 x 1875 x 1400

contenedor 20' PIES
IV550EIVECOC13TE7550500501500400/2303320 x 1875 x 1400

4850 x 1600 x 2000

OPTIONS


Protección del grupo electrógeno. Magnetotérmico.

PROTECTION (MCB)

A generator as energy producing machine installed should take protection against the installation that is to be connected, regardless of the configuration thereof, thus isolating the equipment from possible anomalies.
So we offer magnetothermics and spreads, added to the protection offered by the control board itself.

Conmutación del grupo electrógeno.

COMMUTATION

Indispensable for groups aimed at emergency service, the switchboard provides the operator to launch the boot order to the group to a network failure, and switches the input supply, returning to its natural state after reactivation of the mains.
Made with motorized equipment with manual option and display of electrical parameters, moves over the use of the old systems of contactors.

Protección del grupo electrógeno. Magnetotérmico.

COMMUNICATION

With the optional add-on communications, you can control the generator remotely from a PC, tablet or smartphone, thus accessing to the control of electrical parameters such as alarm notification or testing.

Protección del grupo electrógeno. Magnetotérmico.

SOUNDPROOFING

Perfect both to minimize noise, to their preparation for being outdoors without any additional protection or enclosure.

CUSTOMIZED


By having own design and manufacturing, it allows us to tailor our generating the specific needs of each client group. Therefore if you need a particular feature on a generator, we have the ability to add that feature. We recommend you request a quote if you want to adapt any model to your needs or need more information about a particular model.Request a quote / information.

WARRANTY


The generator is tested at the factory before delivery. Testing voltage, frequency and load are performed, as well as the proper functioning of alarms engine oil temperature and its effect on stop. For carrying a panel F.T.R. (automatic start failure) will be checked by simulating this situation.

LEGISLATION


Our groups have marked "CE" and each comes with the corresponding Declaration of Conformity, which covers the following directives and norms:

  • 2006/42/CE, on the safety of the machines.
  • 2005/88/CE, on noise in the environment by equipment for outdoor use emissions.
  • 2004/108/CE, on electromagnetic compatibility.
  • 2006/88/CE, on the emission of gaseous and particulate pollutants.
  • EN61326/2006 ,on electromagnetic compatibility testing.
  • EN12601-1:2010, on electrical safety tests in the electrical panel.
  • EN12601:2010, on electrical safety tests defined by generator
  • ISO 8532- ISO 3046, on power generator, with barometric reference 100 kPa, 25 ° C and 30% relative humidity.

Download

Reviews

No customer reviews for the moment.

Write a review

GENERATOR WITH DIESEL ENGINE IVECO

GENERATOR WITH DIESEL ENGINE IVECO

Generators IV series, equipped with an IVECO engine of 1500 RPM and a frequency of 50 Hz, has a power range which comprises of 12 to 550 Kva, cooled by water.

Available in the following versions:

  • Open
  • Soundproof

Models available with Diesel engine.